title: Preventive Maintenance for Davis-Standard Gear Reducers – Oil Change Intervals
description: Learn how to prevent costly extrusion line downtime with preventive maintenance for Davis-Standard gear reducers. Follow oil change intervals and maintenance tips for optimal performance.
image: https://davis-standard.com/DS_wordpress/wp-content/uploads/2022/03/Gearcase-on-Skid-1-1024x736.jpg
---

 Jul 25, 2024 11:10:04 PM

# Preventive Maintenance for Davis-Standard Gear Reducers – Oil Change Intervals

[ The Marketing Team ](https://info.davis-standard.com/en/www.davis-standard.com/blog/author/the-marketing-team)

Share: [facebook-f icon ](http://www.facebook.com/share.php?u=https://info.davis-standard.com/en/www.davis-standard.com/blog/preventive-maintenance-for-davis-standard-gear-reducers-oil-change-intervals) [linkedin-in icon ](http://www.linkedin.com/shareArticle?mini=true&url=https://info.davis-standard.com/en/www.davis-standard.com/blog/preventive-maintenance-for-davis-standard-gear-reducers-oil-change-intervals) [envelope icon ](mailto:?body=https://info.davis-standard.com/en/www.davis-standard.com/blog/preventive-maintenance-for-davis-standard-gear-reducers-oil-change-intervals)

![](https://davis-standard.com/DS_wordpress/wp-content/uploads/2022/03/Gearcase-on-Skid-1-1024x736.jpg)

Extrusion line downtime can be expensive. To reduce downtime, it’s important to develop and implement a robust preventive maintenance program for your plastic extruder gear reducer. In this preventative maintenance blog series, we’ll outline three key areas for keeping your gear reducer primed for performance – 1) oil change intervals, 2) flushing the gear reducer, and 3) oil selection.

***Always follow the maintenance information in the manual provided with your equipment.  This blog summarizes general preventative maintenance for the gear reducer.***

#### Oil Change Intervals – Gear Reducer *without* Oil Filtration:

*After the First 200 Hours of Operation (and then every 2,500 hours of operation)*

- - Drain the oil, preferably when warm.
    - Flush and refill system with new oil; refer to the information on the gear reducer nameplate.
    - With the extruder screw rotation stopped, check the oil level and adjust as necessary.
    - Check the alignment of the motor and gear reducer coupling, or belt drive, for proper alignment. Adjust as necessary.

#### Oil Change Intervals, Gear Reducer *with* Oil Filtration:

*After the First 200 Hours of Operation (and then every 4,000 hours of operation)*

- - Drain the oil, preferably when warm.
    - Flush and refill system with new oil. Refer to the information on the gear reducer nameplate.
    - Always replace the oil filter.
    - With the extruder screw rotation stopped, check the oil level and adjust as necessary.
    - Check the alignment of the motor and gear reducer coupling, or belt drive, for proper alignment. Adjust as necessary.
    - If, at any time in between oil changes, the dirty oil filter indicator on the filter head shows red, replace the oil filter.

#### At Every Oil Change

- - Inspect the gear tooth condition visually through the inspection cover. A small amount of wear and a central tooth contact pattern are acceptable.
    - Check for oil leaks.
    - Remove, clean, and reinstall the housing vent plug.
    - Clean and wipe down the external surfaces of the gear reducer.

#### Daily (at shift changes)

- - Listen for any unusual noise. Determine the source and correct as necessary.
    - The maximum continuous operating temperature is 150°F (66°C). Check the temperature using the temperature gauge provided. For reducers not equipped with an oil cooling system, monitor the temperature by hand. Reducers should be warm to the touch, but not hot. Be aware that the temperature may vary with load and speed. For temperature measurements over 150°F (66°C), as measured by an IR pyrometer, camera, or a similar **non-contact tool**, contact the Davis-Standard service department.
    - Look for fluid spills. Clean up when needed and determine the source. Correct as necessary.

#### Monthly

- - Check the oil level in the gear reducer. If it is necessary to routinely add oil, determine the cause of the oil loss and correct it.
    - Inspect the gear reducer and oil cooling system (if supplied) for oil leaks.

We hope you have found this blog helpful! **Please rate this blog below** and be sure to look for the next blog in this series on flushing the gear reducer in April.

For assistance on improving output and quality, or reducing downtime, contact us at 844-MYDAVIS to schedule a service visit or line audit. Our 24/7 customer service is available for your convenience. 

 

Have questions about this blog? Comment below or [**email us**](mailto:marketing@davis-standard.com).

[2022](https://info.davis-standard.com/en/www.davis-standard.com/blog/tag/2022)

## Related posts

[![](https://davis-standard.com/DS_wordpress/wp-content/uploads/2022/04/P-96.3-hi-res.jpg) ](https://info.davis-standard.com/en/www.davis-standard.com/blog/preventive-maintenance-for-davis-standard-gear-reducers-oil-selection)

[2022](https://info.davis-standard.com/en/www.davis-standard.com/blog/tag/2022)

## [Preventive Maintenance for Davis-Standard Gear Reducers – Oil Selection](https://info.davis-standard.com/en/www.davis-standard.com/blog/preventive-maintenance-for-davis-standard-gear-reducers-oil-selection)

[The Marketing Team](https://info.davis-standard.com/en/www.davis-standard.com/blog/author/the-marketing-team) 

 Jul 25, 2024 11:13:21 PM

In the first two blogs of this series, we outlined oil change intervals and the process for...

[ Read more ](https://info.davis-standard.com/en/www.davis-standard.com/blog/preventive-maintenance-for-davis-standard-gear-reducers-oil-selection)

[![](https://davis-standard.com/DS_wordpress/wp-content/uploads/2022/04/JR-extruder-1-1024x875.jpg) ](https://info.davis-standard.com/en/www.davis-standard.com/blog/preventive-maintenance-for-davis-standard-gear-reducers-flushing-the-gear-reducer)

[2022](https://info.davis-standard.com/en/www.davis-standard.com/blog/tag/2022)

## [Preventive Maintenance for Davis-Standard Gear Reducers – Flushing the Gear Reducer](https://info.davis-standard.com/en/www.davis-standard.com/blog/preventive-maintenance-for-davis-standard-gear-reducers-flushing-the-gear-reducer)

[The Marketing Team](https://info.davis-standard.com/en/www.davis-standard.com/blog/author/the-marketing-team) 

 Jul 25, 2024 11:11:45 PM

In the first blog of this series, we outlined oil change intervals. In this blog, we move on to the...

[ Read more ](https://info.davis-standard.com/en/www.davis-standard.com/blog/preventive-maintenance-for-davis-standard-gear-reducers-flushing-the-gear-reducer)

[![](https://info.davis-standard.com/hs-fs/hubfs/image001.png?height=200&name=image001.png) ](https://info.davis-standard.com/en/www.davis-standard.com/blog/smart-solutions-better-processing)

[2018](https://info.davis-standard.com/en/www.davis-standard.com/blog/tag/2018)

## [SMART Solutions = Better Processing](https://info.davis-standard.com/en/www.davis-standard.com/blog/smart-solutions-better-processing)

[The Marketing Team](https://info.davis-standard.com/en/www.davis-standard.com/blog/author/the-marketing-team) 

 Jul 24, 2024 1:04:14 PM

The digital transformation occurring in the plastics industry is opening new doors to efficiency...

[ Read more ](https://info.davis-standard.com/en/www.davis-standard.com/blog/smart-solutions-better-processing)

```json
{
  "@context" : "https://schema.org",
  "@type" : "BlogPosting",
  "author" : {
    "@type" : "Person",
    "name" : "The Marketing Team",
    "url" : "https://info.davis-standard.com/en/www.davis-standard.com/blog/author/the-marketing-team"
  },
  "dateModified" : "2024-07-31T11:46:00.509Z",
  "datePublished" : "2024-07-26T03:10:04.000Z",
  "headline" : "Preventive Maintenance for Davis-Standard Gear Reducers – Oil Change Intervals",
  "image" : [ "https://davis-standard.com/DS_wordpress/wp-content/uploads/2022/03/Gearcase-on-Skid-1-1024x736.jpg" ],
  "mainEntityOfPage" : {
    "@id" : "https://info.davis-standard.com/en/www.davis-standard.com/blog/preventive-maintenance-for-davis-standard-gear-reducers-oil-change-intervals",
    "@type" : "WebPage"
  },
  "publisher" : {
    "@type" : "Organization",
    "logo" : {
      "@type" : "ImageObject",
      "url" : "https://info.davis-standard.com/hubfs/DavisStandard_October2019/Images/logo.svg"
    },
    "name" : "Davis-Standard"
  }
}
```